The VRS response logic in Movilitas.Cloud complies with the GS1 Lightweight Messaging Standard for DSCSA Verification of Product Identifiers, Release 1.3.


The information in the following tables is taken from the document Implementation Guideline - GS1 Lightweight Messaging Standard for DSCSA Verification of Product Identifiers, Release 1.3.


Verification Failure Reason


CodeDescription
"Manufacturer_policy"
Pharmaceutical manufacturers may have different internal policies, which will return a Verified true or false, for the same conditions or determines whether to return additional information with the verification.
"No_match_GTIN_Serial"

No match between GTIN and Serial Number.


(For a serialized product, if GTIN and Serial Number do not match, there is no need to check whether Lot or Expiration Date match).

"No_match_GTIN_Serial_Lot_Expiry"
No match between (GTIN and Serial Number) and Lot Number and Expiration Date.
"No_match_GTIN_Serial_Lot"

No match between (GTIN and Serial Number) and Lot Number.

"No_match_GTIN_Serial_Expiry"
No match between (GTIN and Serial Number) and Expiration Date.
"No_reason_provided"
No reason provided.
"Not_for_re-distribution"
The pharmaceutical manufacturer notifies the Requestor that the product is Suspect and Not for re-distribution.


Additional Information (Optional)


CodeDescription
"Expired"
The product has an expiration date which is in the past.
"ExpirationExtended"
The expiration date has been extended by the FDA for the product being verified.
"Recalled"
The product has been recalled or withdrawn.
"Suspect"
The product's authenticity or integrity is considered suspect by the Responder.
"Illegitimate"
The product's authenticity or integrity is considered illegitimate by the Responder.